Detroit Hoist
Since 1905
Company
About
Employment
Contact
General Terms
Manuals
Equipment Manuals
Hitachi VFD Manuals
Technical
Documentation
Encoder Limits Video
YouTube Channel
Products
Wire Rope Hoists
Bridge Crane End Trucks
Parts Dept.
Replacement Parts
Part Price & Availability
Distributors
Log in
Register
Wire Rope Hoist
Suspension
Monorail
Monorail Cross Mount
Monorail Extended Gauge (Monobox Beam)
Top Running Double Girder
Top Running Double Girder Low Profile
Top Running Double Girder Main / Auxiliary
Base Mount
Lug Mount
Under Running Double Girder
Capacity
3.30 Ton
5.00 Ton
5.50 Ton
8.25 Ton
10.00 Ton
11.00 Ton
15.00 Ton
16.50 Ton
20.00 Ton
25.00 Ton
30.00 Ton
40.00 Ton
50.00 Ton
60.00 Ton
70.00 Ton
75.00 Ton
Atmosphere
Standard
Explosion Proof
Location
Indoor Service
Available Lift
18'-8"
20'-2"
22'-4"
23'-0"
24'-0"
26'-0"
26'-2"
26'-11"
28'-6"
29'-1"
29'-4"
29'-5"
29'-7"
30'-6"
32'-0"
33'-0"
34'-0"
34'-8"
35'-0"
37'-7"
38'-0"
38'-6"
38'-8"
40'-0"
40'-2"
41'-0"
41'-7"
42'-0"
44'-0"
45'-5"
45'-7"
46'-0"
46'-6"
47'-0"
50'-0"
50'-8"
52'-0"
53'-7"
54'-0"
58'-0"
59'-0"
59'-5"
61'-4"
61'-9"
62'-0"
62'-4"
65'-7"
69'-9"
72'-0"
76'-0"
77'-0"
77'-3"
78'-4"
80'-5"
82'-0"
82'-10"
93'-6"
94'-4"
95'-0"
96'-2"
106'-0"
110'-4"
112'-0"
126'-7"
130'-0"
142'-7"
Capacity
Model
Lift
Lift Speed
CMAA Class
Reeving
DWG
Est.Delivery
5.00 Ton
DRB10M28-26
28'-6"
26 FPM
Class D
2 PD
6 - 8 Weeks
3.30 Ton
DB7M41-26
41'-7"
26 FPM
Class D
2 PD
10 - 12 Weeks
3.30 Ton
DB7M59-26
59'-5"
26 FPM
Class D
2 PD
10 - 12 Weeks
5.50 Ton
DB11M41-26
41'-7"
26 FPM
Class D
2 PD
10 - 12 Weeks
5.50 Ton
DB11M59-26
59'-5"
26 FPM
Class D
2 PD
10 - 12 Weeks
3.30 Ton
DB7M77-26
77'-3"
26 FPM
Class D
2 PD
10 - 12 Weeks
8.25 Ton
DB16M26-18
26'-11"
18 FPM
Class D
3 PD
10 - 12 Weeks
11.00 Ton
DB22M20-13
20'-2"
13 FPM
Class D
4 PD
10 - 12 Weeks
5.50 Ton
DB11M77-26
77'-3"
26 FPM
Class D
2 PD
10 - 12 Weeks
8.25 Ton
DB16M38-18
38'-8"
18 FPM
Class D
3 PD
10 - 12 Weeks
8.25 Ton
DB16M41-26
41'-7"
26 FPM
Class D
2 PD
10 - 12 Weeks
11.00 Ton
DB22M29-13
29'-1"
13 FPM
Class D
4 PD
10 - 12 Weeks
8.25 Ton
DB16M59-26
59'-5"
26 FPM
Class D
2 PD
10 - 12 Weeks
8.25 Ton
DB16M50-18
50'-8"
18 FPM
Class D
3 PD
10 - 12 Weeks
11.00 Ton
DB22M26-18
26'-11"
18 FPM
Class D
3 PD
10 - 12 Weeks
11.00 Ton
DB22M38-13
38'-0"
13 FPM
Class D
4 PD
10 - 12 Weeks
8.25 Ton
DB16M77-26
77'-3"
26 FPM
Class D
2 PD
10 - 12 Weeks
11.00 Ton
DB22M26-21
26'-11"
21 FPM
Class D
3 PD
10 - 12 Weeks
11.00 Ton
DB22M38-18
38'-8"
18 FPM
Class D
3 PD
10 - 12 Weeks
16.50 Ton
DB33M20-13
20'-2"
13 FPM
Class D
4 PD
10 - 12 Weeks
11.00 Ton
DB22M38-21
38'-8"
21 FPM
Class D
3 PD
10 - 12 Weeks
16.50 Ton
DB33M20-16
20'-2"
16 FPM
Class D
4 PD
10 - 12 Weeks
16.50 Ton
DB33M29-13
29'-1"
13 FPM
Class D
4 PD
10 - 12 Weeks
11.00 Ton
DB22M50-18
50'-8"
18 FPM
Class D
3 PD
10 - 12 Weeks
16.50 Ton
DB33M29-16
29'-1"
16 FPM
Class D
4 PD
10 - 12 Weeks
11.00 Ton
DB22M50-21
50'-8"
21 FPM
Class D
3 PD
10 - 12 Weeks
16.50 Ton
DB33M38-13
38'-0"
13 FPM
Class D
4 PD
10 - 12 Weeks
16.50 Ton
DB33M38-16
38'-0"
16 FPM
Class D
4 PD
10 - 12 Weeks
Download Drawing
×
PDF
DWG
Detroit Hoist Wire Rope Hoist
×
Construction
Wire rope true vertical lift design.
4-pole, AC squirrel cage, inverter duty rated motors.
Rubber bumpers and drop lugs / rail sweeps.
Premium grade graphite ductile iron wheels and sheaves for durability.
UL508A c UL us listed industrial control panel with listed CSA Type 4, 4X enclosure.
All motions are VFD controlled for smooth operation.
Hoist VFD
Closed loop vector control with motor encoder feedback.
Closed loop vector control provides motor torqure and brake slip safty functions.
Load float control by holding the load at zero speed before setting the motor brake.
Speed control functions supported 2-step maintained, 2-step infinitely variable, 3-step maintained, 3-step infinitely variable, 4-step, 5-step, 0-10V, 4-20mA.
Continuous electronic overload protection.
Programmable hook block limits using simple panel mounted terminal switches to set or reset limit positions.
Micro speed control to provide reduced speeds for critical lifts.
100% dynamic braking to zero speed for increase brake life.
Trolley VFD
Open loop sensorless vector control to provide high starting torque and increase speed/torque regulation for smooth performance.
Speed control functions supported 2-step maintained, 2-step infinitely variable, 3-step maintained, 3-step infinitely variable, 0-10V, 4-20mA, (4-step, 5-step with trolley VFD upgrade),
Continuous electronic thermal-overload protection.
Micro speed control to provide reduced speeds for critical lifts.
Dynamic braking to almost zero speed for increase brake life.
Reduced load swing field configuration using torque limitation and 2-stage acceleration and deceleration times.
Atmosphere
×
Standard Atmosphere
Non-Hazardous atmosphere that do not require protection from fire or explosion hazards due to flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers or flyings.
Explosion Proof Atmosphere
Explosion Proof / Hazardous atmospheres that require protection from fire or explosion hazards due to flammable gases or vapors, flammable liquids, combustible dust, or ignitable fibers or flyings.
Class 1 Div 2 Grp C,D
- Minimum Standard
Class 1 Div 2 Grp C,D Class 2 Div 2 Grp F,G
- Per-Model Standard
Class 1 Div 2 Grp B,C,D
- On Request
Class 1 Div 2 Grp B,C,D Class 2 Div 2 Grp F,G
- On Request
Class 1 Div 1 Grp C,D Class 2 Div 1 Grp F,G
- Per-Model Option
Location
×
Indoor Service
Typically located indoors and not subject to tempature variations causing condensation or direct contact of liquids.
Some models may offer a "
Weather Protection Package
" option that will provide a hoist motor heater, enclosure heater with breather and drain, minimum IP54 rating for all motors, stainless steel brake components, dynamic braking resistor cover, and an extra coat of paint.
Outdoor Service
Subject to tempature variations causing condensation or direct contact of liquids.
Provides
IEEE-841
hoist motor with heater, control enclosure heater with breather and drain, minimum IP55 rating for all motors, totally enclosed motor brake, dynamic braking resistor cover, and an extra coat of paint. (
IEEE-841
trolley motor with heater only with brake option selected)
Capacity
×
The nominal maximum rated capacity.
The capacity can be de-rated to a lower capacity if needed.